PilotGas RegulatorsControls the main valve downstream pressure by adjusting the pilot reducer output pressure, pressure can be set anywhere within the adjusting range, continuous control, achieving continuous, stepless downstream pressure regulation, supports remote, pneumatic and other control modes, downstream pressure is controlled by the reducing valve output pressure, may be equal, or varied at a set ratio, air control ratio 1: 1 to 1:100. Pilot-operated gas regulators are suitable for applications where fluid pressure requires remote or precise control.



● Diaphragm or piston type pressure reducing structure.
Body Thread: 1/2’’-1’’NPT(F).
● Built-in filter screen.
● Can be panel mounted.
● Can be controlled remotely, and other control modes including pneumatic control.
● Compressed air pressure 0-7bar.
● Sensitive operation, high precision.
●multiple pilot reducing valves available.
| Max. Inlet Pressure: 3000psig |
| Outlet Pressure: 0~25, 0~50, 0~100, 0~125, 0~250psig |
| Safety Test Pressure: 1.5 times of max. Inlet pressure |
| Temperature Range: -40℃ to +100℃(above 100° consult technical) |
| Leak rate: Bubble test |
| Cv value: 2, 3.2, 5.1 |
| ➣ air control ratio 1:1 to 1:100 |
| ➣ linearity: Within ±5% F.S |
| ➣ sensitivity: Within ±3% F.S |
| ➣ accuracy: Within ±5% F.S |
| Body: 316L, 304, Brass, C276, TA2, stainless steel pTFE-lined |
| Bonnet: 304 |
| Diaphragm: NBR(nylon lined), Viton(nylon lined), 316L, PTFE |
| Valve Seat: PU, PTFE, PCTFE, PEEK, Vespel |
| Spring: 316L |
| Plug Stem: 316L |
| O-ring: NBR(nitrile rubber), EPDM rubber, viton, PTFE |
| Ordering GuideORDERING INFORMATION | ||||||||
| Series models | Body material | Body port layout | Inlet Pressure | Outlet Pressure | Pressure Gauges | Inlet gas type | Outlet gas type | Options |
| L | B | D | H | G | 02 | 02 | P | |
| XTY61 pilot gas regulator |
L:316L B:Brass S:304 C:C276 T:TA2 CF: PTFE-lined |
A B G J M |
F:500psig E:3000psig |
G:0-250psig H:0-125psig I:0-100psig K:0-50psig L:0-25psig HTY61 outlet pressure: M:0-500psig N:0-1000psig P:0-1500psig Q:0-3000psig |
G: With pressure gauge (Mpa) P: With pressure gauge (psig/bar) W: Without pressure gauge |
04:1/2NPT(F) 06:3/4NPT(F) 08:1"NPT(F) 09:1"NPT(M) Other fittings available |
04:1/2NPT(F) 04:3/4NPT(F) 08:1"NPT(F) 09:1"NPT(M) Other fittings available |
P: Panel-mount mounting R:Relief Valves ZR: Self-venting SR: Self-venting with recovery port |